Optical Smoke Detector

Optical Smoke Detector

An optical smoke detector or photo-electric alarm works on the light scattering principle. The sensor chamber checks for smoke particles every 10 seconds with the help of a pulsed infrared LED beam. These smoke detectors indicate a fire in non-smoking zones. They are used widely by commercial and industrial buildings as a safety measure. A commercial smoke detector sends a signal to the fire control panel while household fire alarms give audible or visual alarms from the detector. Smoke detectors are disc-shaped and set up in plastic enclosures. The process of smoke detection takes place either through ionization or the photoelectric process. The detectors can use either of the two sensing methods. Domestic smoke detectors are interlinked and if one of them detects smoke, all the alarms trigger altogether even if the household power has gone out. Smoke detectors are used mostly in hospitals, gyms, office buildings, industries, malls, and commercial buildings.

 
How do Optical Smoke Detectors work?
 

Smoke detectors work by detecting smoke in the first few seconds of the incident and sending the signal to the fire control alarm panel. The types of detectors vary depending on the indicated fire that they detect. It also depends on the detection principle. Smoke, heat, and flame are three main indicators of fire. The process used for detecting smoke is based on the light-scattering principle. When there is fire, smoke particles enter the optical chamber of smoke detectors. The LED light refracts and scatters on a photodiode. Then, the optical smoke detector sends the fire alarm signal to the control panel.

SKU:

Technical Specification

right icon Model No.: 650
right icon Operating voltage Range: 9 to 32 VDC Volts Non – polarized
right icon Alarm current (Max): ≤ 2 mA
right icon Start-up time: ≤ 30 s
right icon Alarm indicator: Dual Red LEDs
right icon Maximum Alarm Current (LED on): ≤ 55mA @ 24 VDC
right icon Operating Humidity Range: ≤ 10% to 93% Relative Humidity Non- Condensing
right icon Operating Temperature Range: 14o F to 120o F ( -10 C to 49 C)
right icon Height: 2.2” (55mm) installed in base
right icon Weight: 5.5 oz. (155g)
right icon Adjustable Sensitivity: 1-2.5% / FT
right icon Diameter: 4.0” (103 mm)
right icon Reset Voltage: ≤ 3 V
right icon Reset Time: ≤ 30 S

Fill In The Details Below

Get In Touch

Contact Us Now

Adress

#5-4-42 to 50, 1st Floor, Kanhaiya Lal Estate, Distillery Road, Secunderabad-500003 Telangana.

Call Us

+91 9000304158
+91 9963029383

Email Address

sales@smesafety.in
support@smesafety.in

Follow Our Social Media

Fill In The Details Below

× How can I help you?